Respirators are one of the few pieces of safety equipment where the protection depends entirely on the seal between the device and one specific person's face. That is why fit testing exists, and why handing out N95s from a box in the lunchroom is not respiratory protection. Ontario employers must provide the equipment, training and supervision the work requires, and where respirators are used the expected practice is a formal fit testing program aligned with CSA Z94.4. This guide covers who needs testing, how often, what voids a previous test, and what the record should contain.
- 1
Anyone who is required to wear a tight-fitting respirator, including an N95, half-face or full-face respirator, needs a fit test before first use, not after the first exposure
- 2
CSA Z94.4 sets the expected practice for fit testing in Canada and generally calls for re-testing at least every two years, while many programs and clients require annual testing, so follow the stricter requirement you are held to
- 3
Re-test immediately when anything changes the seal: a different make, model or size, significant weight change, dental work or facial surgery, or a new scar or skin condition in the sealing area
- 4
Facial hair in the sealing area prevents a reliable seal, which is why a clean-shaven policy is a respiratory program control rather than a grooming preference
- 5
Do a user seal check every time the respirator is put on, and train workers to recognize when a seal check fails instead of wearing the respirator anyway
- 6
Qualitative testing uses a challenge agent and depends on the worker's sense of taste or smell, while quantitative testing measures leakage with an instrument; know which method your program and clients accept
- 7
Fit testing is not the same as a medical evaluation or a training session, and a fit test record does not prove the worker was trained on donning, doffing, storage or limitations
- 8
Keep a record per worker with the date, the respirator make, model and size, the test method, the pass result and the tester, because an inspector or auditor will ask for all of it
- 9
Fit testing does not make a hazard disappear: if the exposure is above the protection factor of the respirator, the answer is engineering control or ventilation, not a tighter mask
- 10
For construction tasks such as cutting or grinding silica-containing material, pair fit testing with water suppression, on-tool extraction and clean break areas, because respirators are the last line of defence